- Aço
- Originais unhas de agarre - trave o parafuso no lugar enquanto a porca é enroscada
- Cabeça do parafuso de grande diâmetro
- Parafuso de cabeça lisa - reduz o risco de rasgo
- Extensivamente testado e usado em indústrias agriculturais nos EUA
- Apropriado para furos lisos ou côncavos
- Tipos: M6, M8, M10
Specifications
Fang | Size | Size | Head Diameter | Max. Torque | Package Quantity | Package Weight |
(mm) | (in.) | (mm) | (Nm) | (kgs) | ||
M6 x 20 | 1/4 x 3/4* | 25 | 11 | 100 | 1.56 | |
M6 x 25 | 1/4 x 1 | 25 | 11 | 100 | 1.82 | |
M8 x 25 | 5/16 x 1* | 30 | 27 | 100 | 2.76 | |
M8 x 30 | 5/16 x 1-1/4 | 30 | 27 | 100 | 3.02 | |
M8 x 40 | 5/16 x 1-1/2 | 30 | 27 | 100 | 3.24 | |
M10 x 30 | 3/8 x 1-1/4 | 35 | 37 | 100 | 4.90 | |
M10 x 35 | 3/8 x 1-1/3 | 35 | 37 | 100 | 5.12 | |
M10 x 40 | 3/8 x 1-1/2 | 35 | 37 | 100 | 5.34 | |
M10 x 45 | 3/8 x 1-3/4 | 35 | 37 | 100 | 5.56 | |
Standard zinc plated; self colour and stainless options on request.
Downloads
Accessories
Ferragens para parafusos de elevador
Além de vários tipos e tamanhos de parafusos para elevador, a 4B oferece as ferragens necessárias para cada fixador.
Para obter mais informação sobre as especificações das ferragens para parafusos de elevador, consulte a nosso catálogo de parafusos.
FAQ's
Is the installation of fang bolts any different to other elevator bolts?
Fanged bolts are a little more unique than other elevator bolts. Install fanged bolts with fang tips in-line across the
width of the belt. Placing the fangs in such a manner minimizes stresses caused by the flat head going
around the curved pulley. Set the fangs into the belt cover by tapping them with a mallet. Once the bolt is tightened, the
fangs will draw up into the belt and the head will seat properly.
FAQ - Elevator Bolts
How long of an elevator bolt do I need?
When installing buckets on an elevator belt, use this simple formula:
(belt thickness + bucket back thickness + washer thickness + nut thickness + 1/4 inch)
What grade are 4B elevator bolts?
4B elevator bolts meet or exceed ISO Grade 5.8 / SAE Grade 2 standards. The bolt grade guide below is for bolt diameters of 6mm (1/4") to 12mm (1/2"):
BOLT GRADE GUIDE:
ISO Grade | SAE Grade | Min. Tensile Strenghth (psi) |
---|---|---|
5.8 | 2 | 74000 |
8.8 | 5 | 120000 |
10.9 | 8 | 150000 |
What torque setting should I use?
An ideal installation will result in the elevator bolt head fitting snuggly just below the surface of the belt after tightening (Image B). However, never exceed the maximum recommended torque as shown in the tables below:
MAXIMUM RECOMMENDED TORQUE FOR 4B ELEVATOR BOLTS METRIC ISO GRADE 5.8
Bolt Dia. | in. lbs. | ft. lbs. | nm |
---|---|---|---|
M6 | 72 | 6 | 8 |
M7 | 115 | 10 | 13 |
M8 | 168 | 14 | 19 |
M10 | 336 | 28 | 38 |
M12 | 588 | 49 | 66 |
MAXIMUM RECOMMENDED TORQUE FOR 4B ELEVATOR BOLTS SAE GRADE 2 OR 302 STAINLESS STEEL
bolt dia. | in. lbs. | ft. lbs | nm |
---|---|---|---|
1/4" | 72 | 6 | 8 |
5/16" | 156 | 13 | 18 |
3/8" | 276 | 23 | 31 |
1/2" | 684 | 57 | 77 |
How do you install an elevator bolt?
The head of the elevator bolt should lie against the inside surface of the elevator belt with the nuts and washers on the inside of the elevator bucket. An ideal installation will result in the elevator bolt head fitting snuggly just below the surface of the elevator belt.
Do you have any maintenance recommendations?
After initial installation, it is recommended that the bucket elevator be run for approximately four hours. After which the bolts should be re-tightened to ensure that there are no loose parts. Periodic inspections are always recommended to check for any issues that may occur during the life of the elevator, including checks for loose or damaged elevator bolts.
Design Services
Desenho técnico de elevadores de caçambas
Desenho técnico de elevadores de caçambas
A 4B desenhou centenas de elevadores de caçambas para todas as indústrias, incluindo rações para animais, manuseamento de grãos, moagem de farinha, maltagem e fabricação de cerveja, cimento, carvão e outras indústrias pesadas.
Aproveite o serviço de assistência técnica mundial, garantido e sem custos da 4B e beneficie dos conhecimentos de uma equipa de engenheiros especializados no design e cálculo de elevadores de caçambas. Com base nos seus dados técnicos mais importantes, os nossos engenheiros podem fazer uma recomendação técnica detalhada para o elevador de balde certo, com as caraterísticas de capacidade e descarga ideais. Podemos desenhar um novo elevador ou ajudá-lo a aumentar a capacidade do seu atual elevador.
Obter um cálculo de elevador de caçambas gratuito
Preencha este formulário da forma mais precisa possível para que a sua consulta seja atendida de forma mais eficaz.
A 4B desenhou centenas de elevadores de caçambas para todas as indústrias, incluindo rações para animais, manuseamento de grãos, moagem de farinha, maltagem e fabricação de cerveja, cimento, carvão e outras indústrias pesadas.
Aproveite o serviço de assistência técnica mundial, garantido e sem custos da 4B e beneficie dos conhecimentos de uma equipa de engenheiros especializados no design e cálculo de elevadores de caçambas. Com base nos seus dados técnicos mais importantes, os nossos engenheiros podem fazer uma recomendação técnica detalhada para o elevador de balde certo, com as caraterísticas de capacidade e descarga ideais. Podemos desenhar um novo elevador ou ajudá-lo a aumentar a capacidade do seu atual elevador.
Obter um cálculo de elevador de caçambas gratuito
Preencha este formulário da forma mais precisa possível para que a sua consulta seja atendida de forma mais eficaz.