- Acciaio / Acciaio inossidabile 304 e 316
- Ca. DIN 15237
- ISO classe 5.8 (superiore al DIN)
- Testa del bullone larga
- Completamente filettato, zincato o in acciao inossidabile
- Tipi: M6, M7, M8, M10, M12
Specifications
Euro | Size | Head Diameter | Max. Torque | Package Quantity | Package Weight |
bolts | (mm) | (mm) | (Nm) | (kg) | |
M6 x 20 | 21 | 8 | 100 | 1.28 | |
M6 x 25 | 21 | 8 | 100 | 1.38 | |
M6 x 30 | 21 | 8 | 100 | 1.5 | |
M7 x 20 | 23 | 13 | 100 | 1.82 | |
M7 x 22 | 23 | 13 | 100 | 1.94 | |
M7 x 25 | 23 | 13 | 100 | 2.1 | |
M7 x 30 | 23 | 13 | 100 | 2.16 | |
M7 x 35 | 23 | 13 | 100 | 2.22 | |
M8 x 20 | 28 | 25*** | 20 | 100 | 2.98 | |
M8 x 22 | 28 | 25*** | 20 | 100 | 2 | |
M8 x 25 | 28 | 25*** | 20 | 100 | 3 | |
M8 x 30 | 28 | 25*** | 20 | 100 | 3.02 | |
M8 x 35 | 28 | 25*** | 20 | 100 | 3.37 | |
M8 x 40 | 28 | 25*** | 20 | 100 | 3.72 | |
M8 x 45 | 28 | 25*** | 20 | 100 | 3.88 | |
M8 x 50 | 28 | 25*** | 20 | 100 | 3.94 | |
M10 x 25 | 35 | 31*** | 36 | 100 | 5.42 | |
M10 x 30 | 35| 31*** | 36 | 100 | 5.43 | |
M10 x 35 | 35 | 31*** | 36 | 100 | 5.44 | |
M10 x 40 | 35 | 31*** | 36 | 100 | 5.84 | |
M10 x 45 | 35 | 31*** | 36 | 100 | 6.02 | |
M10 x 50 | 35 | 31*** | 36 | 100 | 6.18 | |
M12 x 40* | 42 | 65 | 100 | 9.24 | |
M12 x 50* | 42 | 65 | 100 | 4.96** | |
M12 x 60* | 42 | 65 | 100 | 5.36** | |
M12 x 70* | 42 | 65 | 100 | 5.60** |
* Not available in stainless steel.
Downloads
Accessories
Bulloni per elevatori - ACCESSORI
- Acciaio / Acciaio inossidabile 316
- Rondelle ovali larghe
- Dadi autobloccanti con inserto in nylon con filettatura metrica (DIN 985)
- Dadi autobloccanti con inserto in nylon con filettatura BSW
- Controdadi esagonali (dadi bassi)
- Rondelle piane larghe per fissaggio su materiali non metallici
- Rondelle distanziatrici HDP
- Rondelle di gomma ...
FAQ's
FAQ - Elevator Bolts
How long of an elevator bolt do I need?
When installing buckets on an elevator belt, use this simple formula:
(belt thickness + bucket back thickness + washer thickness + nut thickness + 1/4 inch)
What grade are 4B elevator bolts?
4B elevator bolts meet or exceed ISO Grade 5.8 / SAE Grade 2 standards. The bolt grade guide below is for bolt diameters of 6mm (1/4") to 12mm (1/2"):
BOLT GRADE GUIDE:
ISO Grade | SAE Grade | Min. Tensile Strenghth (psi) |
---|---|---|
5.8 | 2 | 74000 |
8.8 | 5 | 120000 |
10.9 | 8 | 150000 |
What torque setting should I use?
An ideal installation will result in the elevator bolt head fitting snuggly just below the surface of the belt after tightening (Image B). However, never exceed the maximum recommended torque as shown in the tables below:
MAXIMUM RECOMMENDED TORQUE FOR 4B ELEVATOR BOLTS METRIC ISO GRADE 5.8
Bolt Dia. | in. lbs. | ft. lbs. | nm |
---|---|---|---|
M6 | 72 | 6 | 8 |
M7 | 115 | 10 | 13 |
M8 | 168 | 14 | 19 |
M10 | 336 | 28 | 38 |
M12 | 588 | 49 | 66 |
MAXIMUM RECOMMENDED TORQUE FOR 4B ELEVATOR BOLTS SAE GRADE 2 OR 302 STAINLESS STEEL
bolt dia. | in. lbs. | ft. lbs | nm |
---|---|---|---|
1/4" | 72 | 6 | 8 |
5/16" | 156 | 13 | 18 |
3/8" | 276 | 23 | 31 |
1/2" | 684 | 57 | 77 |
How do you install an elevator bolt?
The head of the elevator bolt should lie against the inside surface of the elevator belt with the nuts and washers on the inside of the elevator bucket. An ideal installation will result in the elevator bolt head fitting snuggly just below the surface of the elevator belt.
Do you have any maintenance recommendations?
After initial installation, it is recommended that the bucket elevator be run for approximately four hours. After which the bolts should be re-tightened to ensure that there are no loose parts. Periodic inspections are always recommended to check for any issues that may occur during the life of the elevator, including checks for loose or damaged elevator bolts.
Design Services
Progettazione di elevatori a tazze
Progettazione di elevatori a tazze
In 4B abbiamo progettato centinaia di tazze per elevatore per tutti i settori dell’ industria dell’ alimentazione animale, stoccaggio cereali, macinatura, e per cementerie ed altre industrie pesanti. Approfitta del servizio gratuito della 4B che ti garantisce un supporto tecnico a livello mondiale usufruendo del servizio di un team di ingegneri specializzati nella progettazione di elevatori e trasportatori.
Utilizzando i dati comunicati i nostri ingegneri saranno in grado di fornirvi suggerimenti tecnici dettagliati sul tipo di tazza, sulla capacità ideale e sulle caratteristiche di scarico. Siamo in grado di progettare il Vostro nuovo elevatore a tazza o Vi possiamo aiutare ad aumentare la portata di quello già esistente.
Per ottenere una progettazione gratuita
Vi preghiamo di completare il più accuratamente possibile questo questionario per aiutarci a dare risposte nel modo più efficace possible alle Vostre domande.
In 4B abbiamo progettato centinaia di tazze per elevatore per tutti i settori dell’ industria dell’ alimentazione animale, stoccaggio cereali, macinatura, e per cementerie ed altre industrie pesanti. Approfitta del servizio gratuito della 4B che ti garantisce un supporto tecnico a livello mondiale usufruendo del servizio di un team di ingegneri specializzati nella progettazione di elevatori e trasportatori.
Utilizzando i dati comunicati i nostri ingegneri saranno in grado di fornirvi suggerimenti tecnici dettagliati sul tipo di tazza, sulla capacità ideale e sulle caratteristiche di scarico. Siamo in grado di progettare il Vostro nuovo elevatore a tazza o Vi possiamo aiutare ad aumentare la portata di quello già esistente.
Per ottenere una progettazione gratuita
Vi preghiamo di completare il più accuratamente possibile questo questionario per aiutarci a dare risposte nel modo più efficace possible alle Vostre domande.