Ref70 | Size | Size | Head Diameter | Max. Torque | Package Quantity | Package Weight |
(mm) | (in.) | (mm) | (Nm) | (kgs) | ||
M6 x 12 | 1/4 x 1/2 | 17 | 5 | 100 | 1.04 | |
M6 x 20* | 1/4 x 3/4 | 17 | 5 | 100 | 1.18 | |
M6 x 25* | 1/4 x 1 | 17 | 5 | 100 | 1.24 | |
M6 x 30 | 1/4 x 1-1/4 | 17 | 5 | 100 | 1.48 | |
M6 x 40 | 1/4 x 1-1/2 | 17 | 5 | 100 | 1.56 | |
M8 x 20 | 5/16 x 3/4 | 23 | 10 | 100 | 2.08 | |
M8 x 25* | 5/16 x 1 | 23 | 10 | 100 | 2.38 | |
M8 x 30* | 5/16 x 1-1/4 | 23 | 10 | 100 | 3.54 | |
M8 x 40* | 5/16 x 1-1/2 | 23 | 10 | 100 | 2.90 | |
M8 x 50 | 5/16 x 2 | 23 | 10 | 100 | 3.24 | |
M10 x 25 | 3/8 x 1 | 27 | 18 | 100 | 3.94 | |
M10 x 30* | 3/8 x 1-1/4 | 27 | 18 | 100 | 4.44 | |
M10 x 40* | 3/8 x 1-1/2 | 27 | 18 | 100 | 4.80 | |
M10 x 45* | 3/8 x 1-3/4 | 27 | 18 | 100 | 5.08 | |
M10 x 50* | 3/8 x 2 | 27 | 18 | 100 | 5.36 | |
M10 x 55 | 3/8 x 2-1/4 | 27 | 18 | 100 | 5.50 | |
M10 x 65 | 3/8 x 2-1/2 | 27 | 18 | 100 | 5.72 | |
M12 x 30 | 1/2 x 1-1/4 | 35 | 42 | 100 | 7.44 | |
M12 x 40 | 1/2 x 1-1/2 | 35 | 42 | 100 | 7.78 | |
M12 x 45 | 1/2 x 1-3/4 | 35 | 42 | 100 | 8.12 | |
M12 x 50 | 1/2 x 2 | 35 | 42 | 100 | 8.44 | |
M12 x 55 | 1/2 x 2-1/4 | 35 | 42 | 100 | 9.08 | |
* Available in stainless steel
Downloads
Accessories
Large Oval Washers
Use with Ref 70 bolts in heavy duty applications.
- Available in Zinc-Plated Steel / Stainless Steel 304
- Locates over 4 lugs on bolt head, increasing effective bolt head size and bolt holding
- Belt must be thick enough to absorb the washer and / or the bucket belt holes should be recessed
- Not recommended on pulley diameters of less than 20” (500mm)
- Fit the longest part of the oval across the belt width
Bulloni per elevatori - ACCESSORI
- Acciaio / Acciaio inossidabile 316
- Rondelle ovali larghe
- Dadi autobloccanti con inserto in nylon con filettatura metrica (DIN 985)
- Dadi autobloccanti con inserto in nylon con filettatura BSW
- Controdadi esagonali (dadi bassi)
- Rondelle piane larghe per fissaggio su materiali non metallici
- Rondelle distanziatrici HDP
- Rondelle di gomma ...
FAQ's
Is the installation of Ref70 bolts any different to other elevator bolts?
When using the large Reference 70™ (REF 70™) oval washer with the REF 70™ bolt, the washer should be placed with the widest part across the belt in order to minimize stress on the system as it passes around the curved pulley.
Note: the bolt head and oval washer are installed on the back of the belt.
FAQ - Elevator Bolts
How long of an elevator bolt do I need?
When installing buckets on an elevator belt, use this simple formula:
(belt thickness + bucket back thickness + washer thickness + nut thickness + 1/4 inch)
What grade are 4B elevator bolts?
4B elevator bolts meet or exceed ISO Grade 5.8 / SAE Grade 2 standards. The bolt grade guide below is for bolt diameters of 6mm (1/4") to 12mm (1/2"):
BOLT GRADE GUIDE:
ISO Grade | SAE Grade | Min. Tensile Strenghth (psi) |
---|---|---|
5.8 | 2 | 74000 |
8.8 | 5 | 120000 |
10.9 | 8 | 150000 |
What torque setting should I use?
An ideal installation will result in the elevator bolt head fitting snuggly just below the surface of the belt after tightening (Image B). However, never exceed the maximum recommended torque as shown in the tables below:
MAXIMUM RECOMMENDED TORQUE FOR 4B ELEVATOR BOLTS METRIC ISO GRADE 5.8
Bolt Dia. | in. lbs. | ft. lbs. | nm |
---|---|---|---|
M6 | 72 | 6 | 8 |
M7 | 115 | 10 | 13 |
M8 | 168 | 14 | 19 |
M10 | 336 | 28 | 38 |
M12 | 588 | 49 | 66 |
MAXIMUM RECOMMENDED TORQUE FOR 4B ELEVATOR BOLTS SAE GRADE 2 OR 302 STAINLESS STEEL
bolt dia. | in. lbs. | ft. lbs | nm |
---|---|---|---|
1/4" | 72 | 6 | 8 |
5/16" | 156 | 13 | 18 |
3/8" | 276 | 23 | 31 |
1/2" | 684 | 57 | 77 |
How do you install an elevator bolt?
The head of the elevator bolt should lie against the inside surface of the elevator belt with the nuts and washers on the inside of the elevator bucket. An ideal installation will result in the elevator bolt head fitting snuggly just below the surface of the elevator belt.
Do you have any maintenance recommendations?
After initial installation, it is recommended that the bucket elevator be run for approximately four hours. After which the bolts should be re-tightened to ensure that there are no loose parts. Periodic inspections are always recommended to check for any issues that may occur during the life of the elevator, including checks for loose or damaged elevator bolts.
Design Services
Progettazione di elevatori a tazze
Progettazione di elevatori a tazze
In 4B abbiamo progettato centinaia di tazze per elevatore per tutti i settori dell’ industria dell’ alimentazione animale, stoccaggio cereali, macinatura, e per cementerie ed altre industrie pesanti. Approfitta del servizio gratuito della 4B che ti garantisce un supporto tecnico a livello mondiale usufruendo del servizio di un team di ingegneri specializzati nella progettazione di elevatori e trasportatori.
Utilizzando i dati comunicati i nostri ingegneri saranno in grado di fornirvi suggerimenti tecnici dettagliati sul tipo di tazza, sulla capacità ideale e sulle caratteristiche di scarico. Siamo in grado di progettare il Vostro nuovo elevatore a tazza o Vi possiamo aiutare ad aumentare la portata di quello già esistente.
Per ottenere una progettazione gratuita
Vi preghiamo di completare il più accuratamente possibile questo questionario per aiutarci a dare risposte nel modo più efficace possible alle Vostre domande.
In 4B abbiamo progettato centinaia di tazze per elevatore per tutti i settori dell’ industria dell’ alimentazione animale, stoccaggio cereali, macinatura, e per cementerie ed altre industrie pesanti. Approfitta del servizio gratuito della 4B che ti garantisce un supporto tecnico a livello mondiale usufruendo del servizio di un team di ingegneri specializzati nella progettazione di elevatori e trasportatori.
Utilizzando i dati comunicati i nostri ingegneri saranno in grado di fornirvi suggerimenti tecnici dettagliati sul tipo di tazza, sulla capacità ideale e sulle caratteristiche di scarico. Siamo in grado di progettare il Vostro nuovo elevatore a tazza o Vi possiamo aiutare ad aumentare la portata di quello già esistente.
Per ottenere una progettazione gratuita
Vi preghiamo di completare il più accuratamente possibile questo questionario per aiutarci a dare risposte nel modo più efficace possible alle Vostre domande.