REF 70™ - pultit
Ref70 elevator bolts
Product Features
  • teräs / ruostumaton teräs 304 & 316
  • teräs - ISO-luokka 5.8
  • kovera kanta, jossa 4 tappia alapuolella estämässä pyörimistä pulttia kiristettäessä
  • tuuma- tai mm-mitoitus
Bolt Material
Stainless Steel
Steel - self colour (on request)
Steel (zinc plated)
    ref70-bolt-measurement
    Ref70 Size Size Head Diameter Max. Torque Package Quantity Package Weight
    (mm) (in.) (mm) (Nm) (kgs)
    M6 x 12 1/4 x 1/2 17 5 100 1.04
    M6 x 20* 1/4 x 3/4 17 5 100 1.18
    M6 x 25* 1/4 x 1 17 5 100 1.24
    M6 x 30 1/4 x 1-1/4 17 5 100 1.48
    M6 x 40 1/4 x 1-1/2 17 5 100 1.56
    M8 x 20 5/16 x 3/4 23 10 100 2.08
    M8 x 25* 5/16 x 1 23 10 100 2.38
    M8 x 30* 5/16 x 1-1/4 23 10 100 3.54
    M8 x 40* 5/16 x 1-1/2 23 10 100 2.90
    M8 x 50 5/16 x 2 23 10 100 3.24
    M10 x 25 3/8 x 1 27 18 100 3.94
    M10 x 30* 3/8 x 1-1/4 27 18 100 4.44
    M10 x 40* 3/8 x 1-1/2 27 18 100 4.80
    M10 x 45* 3/8 x 1-3/4 27 18 100 5.08
    M10 x 50* 3/8 x 2 27 18 100 5.36
    M10 x 55 3/8 x 2-1/4 27 18 100 5.50
    M10 x 65 3/8 x 2-1/2 27 18 100 5.72
    M12 x 30 1/2 x 1-1/4 35 42 100 7.44
    M12 x 40 1/2 x 1-1/2 35 42 100 7.78
    M12 x 45 1/2 x 1-3/4 35 42 100 8.12
    M12 x 50 1/2 x 2 35 42 100 8.44
    M12 x 55 1/2 x 2-1/4 35 42 100 9.08

    * Available in stainless steel

    Literature Downloads

    Large Oval Washers

    Large Oval Washer
    Large Oval Washers

    Use with Ref 70 bolts in heavy duty applications.

    • Available in Zinc-Plated Steel / Stainless Steel 304
    • Locates over 4 lugs on bolt head, increasing effective bolt head size and bolt holding
    • Belt must be thick enough to absorb the washer and / or the bucket belt holes should be recessed
    • Not recommended on pulley diameters of less than 20” (500mm)
    • Fit the longest part of the oval across the belt width
    PRODUCT DETAILS

    Elevaattoripultit - TARVIKKEET

    Nuts, Spacers, Washers
    Elevaattoripultit - TARVIKKEET
    • teräs / ruostumaton teräs 316
    • iso, ovaali aluslevy
    • mm-mitoitetut itselukittuvat Nylon-mutterit (DIN 985)
    • itselukittuvat BSW Nylon-mutterit (P-malli)
    • kuusikulmaiset lukkomutterit
    • Iso korinaluslevy
    • HDP-aluslevy
    • Kumialuslevyt
    PRODUCT DETAILS

    Is the installation of Ref70 bolts any different to other elevator bolts?

    When using the large Reference 70™ (REF 70™) oval washer with the REF 70™ bolt, the washer should be placed with the widest part across the belt in order to minimize stress on the system as it passes around the curved pulley. 

    Note:  the bolt head and oval washer are installed on the back of the belt.  
         
    Ref70 installation

    FAQ - Elevator Bolts

    FAQ - Elevator Bolts

    How long of an elevator bolt do I need?  
      When installing buckets on an elevator belt, use this simple formula:  
      (belt thickness + bucket back thickness + washer thickness + nut thickness + 1/4 inch)  
         
    What grade are 4B elevator bolts?  
      4B elevator bolts meet or exceed ISO Grade 5.8 / SAE Grade 2 standards.  The bolt grade guide below is for bolt diameters of 6mm (1/4") to 12mm (1/2"):  
         
    BOLT GRADE GUIDE:

    ISO Grade SAE Grade Min. Tensile Strenghth (psi)
    5.8 2 74000
    8.8 5 120000
    10.9 8 150000


    What torque setting should I use?  
      An ideal installation will result in the elevator bolt head fitting snuggly just below the surface of the belt after tightening (Image B).  However, never exceed the maximum recommended torque as shown in the tables below:  
         
    MAXIMUM RECOMMENDED TORQUE FOR 4B ELEVATOR BOLTS METRIC ISO GRADE 5.8

    Bolt Dia. in. lbs. ft. lbs. nm
    M6 72 6 8
    M7 115 10 13
    M8 168 14 19
    M10 336 28 38
    M12 588 49 66


    MAXIMUM RECOMMENDED TORQUE FOR 4B ELEVATOR BOLTS SAE GRADE 2 OR 302 STAINLESS STEEL

    bolt dia. in. lbs. ft. lbs nm
    1/4" 72 6 8
    5/16" 156 13 18
    3/8" 276 23 31
    1/2" 684 57 77

     

    How do you install an elevator bolt?  
      The head of the elevator bolt should lie against the inside surface of the elevator belt with the nuts and washers on the inside of the elevator bucket.  An ideal installation will result in the elevator bolt head fitting snuggly just below the surface of the elevator belt.    
         
       Overview        installations


         
      Do you have any maintenance recommendations?  
      After initial installation, it is recommended that the bucket elevator be run for approximately four hours.  After which the bolts should be re-tightened to ensure that there are no loose parts.  Periodic inspections are always recommended to  check for any issues that may occur during the life of the elevator, including checks for loose or damaged elevator bolts.  

    Bucket Elevator Design Service

    Bucket Elevator Design Service

    At 4B, we have designed hundreds of bucket elevators for all industries, including Animal Feed, Grain Handling, Flour Milling, Malting & Brewing through to Cement, Coal and other heavy industries.

    Take advantage of 4B's free, guaranteed worldwide technical support service from a team of engineers specialising in the design and calculation of bucket elevators.. Using your key technical data, our engineers can give you a detailed technical recommendation for the ideal bucket elevator with the ideal capacity and discharge characteristics. We can either design your new bucket elevator or we can help you to increase the capacity of your existing bucket elevator.

    To get a free bucket elevator calculation

    Please fill this form in as accurately as possible to allow us to deal with your enquiry more effectively. 

    At 4B, we have designed hundreds of bucket elevators for all industries, including Animal Feed, Grain Handling, Flour Milling, Malting & Brewing through to Cement, Coal and other heavy industries.

    Take advantage of 4B's free, guaranteed worldwide technical support service from a team of engineers specialising in the design and calculation of bucket elevators.. Using your key technical data, our engineers can give you a detailed technical recommendation for the ideal bucket elevator with the ideal capacity and discharge characteristics. We can either design your new bucket elevator or we can help you to increase the capacity of your existing bucket elevator.

    To get a free bucket elevator calculation